Browsing by Subject "solar collector"
Now showing 1 - 8 of 8
- Results Per Page
- Sort Options
Item type:Thesis, Access status: Restricted , Analiza funkcjonowania systemów wykorzystujących odnawialne źródła energii na przykładzie doświadczalnej stacji badawczej w Laboratorium Edukacyjno - Badawczym Odnawialnych Źródeł i Poszanowania Energii AGH w Miękini(Data obrony: 2014-07-11) Sapeta, Adam
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaThis study describes functioning of installations using renewable energy sources installed in Laboratory of AGH in Miękinia. In order to provide thermal comfort and hot water in the building installed four heat pumps have been installed: two heat pumps Viessmann Vitocal 300 – G BW 301.A17 and two heat pumps Vaillant geoTHERM plus VWS 104/2. Ground is used as a lower heat source. The work of heat pumps is supported by the fields of solar collector: two fields of cured – vacuum collectors and one field of flat plate collectors.Item type:Thesis, Access status: Restricted , Analiza porównawcza systemów: fotowoltaicznego oraz fototermicznego do wytwarzania CWU(Data obrony: 2013-11-15) Pasierb, Agnieszka
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaIn recent years there is a significant increase in interest in renewable energy sources. Most common solar energy installation throughout polish households is a solar collector system which support the production of domestic hot water. At present also more and more popular become photovoltaic systems which produce power used, for example, to heathen up the water in household boilers. The main subject of the following master's thesis is to compare the solar thermal systems to the photovoltaic systems with the usage of Polysun software. The main purpose of this comparison is to highlight the advantages and disadvantages of each system with focus on economic and ecological aspects. The result of this process is that there is no strong advantage of one system with reference to another. However, focusing of a critical category of system implementation costs one can come up to result, that the installation of photothermal system is more cost-effective. There is a strong possibility, that in the future both, photovoltaic and solar thermal systems, will characterize with similar technical features and financial effectiveness.Item type:Thesis, Access status: Restricted , Analiza techniczno-ekonomiczna koncepcji projektowej instalacji centralnego ogrzewania i ciepłej wody użytkowej z wykorzystaniem systemu OŹE w budynku użyteczności publicznej(Data obrony: 2016-06-29) Szendzielorz, Anna
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaCelem pracy było zaprojektowanie instalacji centralnego ogrzewania i ciepłej wody użytkowej z wykorzystaniem pompy ciepła i kolektorów słonecznych. Przedstawione zostały podstawy technologii pomp ciepła i kolektorów słonecznych. Na podstawie danych technicznych budynku i wykonanych obliczeń dobrano sprężarkową pompę ciepła wraz z pionowym wymiennikiem gruntowy oraz instalacje płaskich kolektorów słonecznych. Wykonana została również analiza ekonomiczna i ekologiczna zaproponowanego rozwiązania.Item type:Thesis, Access status: Restricted , Koncepcja fasady opartej na ogniwach PVT dla wybranego budynku jednorodzinnego(Data obrony: 2014-12-10) Mętel, Monika
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaThe following thesis project shows the conception of photovoltaic facade based on photovoltaic thermal hybrid (PVT) solar collectors for a single-family house. First part of project presents ways of using solar radiation, and a short description of used necessary devices. It also describes the condition of solar energy utilization worldwide. In the second part of project the energy yield of hybrid solar installation on the facade of the building was calculated. Then, the calculation result was compared with the outcome for the same installation placed on the roof of the building. Calculations were also made for the case in which the PVT facade was supported by traditional photovoltaic panels.Item type:Thesis, Access status: Restricted , Metoda wyznaczenia sprawności kolektorów słonecznych(Data obrony: 2011-11-29) Gil, Wojciech
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaAt the work methods of appointing the efficiency of solar collectors were discussed. Information was entered into about examinations conducted according to the Polish norm PN-EN 12975-1 and PN-EN 12975-2. Ways of raising the efficiency of collectors, on the basis of studies conducted by the Institute for Renewable Energy were also described. An efficiency of flat manifolds of liquid different companies was compared and an analysis of the work of the mighty superficial collector of the ENSOL company, whose study was performed in accordance with the standard.Item type:Thesis, Access status: Restricted , Modernizacja systemu grzewczego z wykorzystaniem odnawialnych źródeł energii dla domu jednorodzinnego(Data obrony: 2014-07-11) Kwasek, Sylwia
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaIn the master’ s thesis was presented modernization of the heating system base on a heat pump and solar collectors. Devices were selected and heat energy demand was calculated. Economic analysis showed investment costs as well as operating costs in this project. Also shown how obtaining grants impact on payback time. In the ecological analysis was calculated avoided emissions to air.Item type:Thesis, Access status: Restricted , Porównanie sprawności kolektorów słonecznych(Data obrony: 2017-01-19) Trzcińska, Jowita
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaW pracy omówiono podstawowe typy kolektorów płaskich i próżniowo-rurowych oraz przedstawiono porównanie ich sprawności. Wybrano do porównania 10 kolektorów producentów obecnych na polskim rynku. W oparciu o wybrane parametry i normę EN-PL: 12975:2006 wykonano obliczenia dotyczące sprawności kolektorów i sporządzono wykresy porównawcze. Obliczenia uzysku energii dokonano dla przyjętych założeń i warunków dla Polski środkowo-wschodniej. Po przeprowadzonej analizie stwierdzono, że najlepsze wyniki uzyskał kolektor firmy Viessmann-Vitosol-300T.Item type:Thesis, Access status: Restricted , Projekt koncepcyjny solarnego systemu wytwarzania CWU dla budynku Tarnowskiej Agencji Rozwoju Regionalnego w Tarnowie(Data obrony: 2010-10-12) Konieczny, Piotr
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaThe purpose of writing this project was to design a solar instalment for the building of Tarnowska Agencja Rozwoju Regionalnego in Tarnow from an academic point of view. The instalment mainly consists of solar collectors, a solar container, a solar pump and a security receptacle. A number of calculations revealed parameters, which were used to choose above- -mentioned devices. Next, there were pointed out equivalents of those devices, accessible on the market. Next chapter included an economical and ecological analysis of the instalment. Basing on this, the final conclusions and opinion on profitability were made.