  • Item type:Article, Access status: Open Access ,
    Numeryczna symulacja procesu wentylacji w wyrobiskach ślepych
    (Wydawnictwa AGH, 2005) Branny, Marian
    The study explores the potential of numerical modelling of airflow in blind headings. The main focus is forecasting the ventilation parameters in headings and galleries characteristic of copper mines belonging to the LGOM Corporation. The fundamentals of mathematical modelling of turbulent flows are provided. The model makes use of 3D continuity and Rynolds equations, the equation of turbulent transport of chemical components and the equations of the k-$\epsilon$ model (kinetic energy of turbulence, the rate of kinetic energy dissipation). The discretisation procedure involved the control volume method and the technique UPWIND. The developed numerical codes employ the hybrid schemes and power-law techniques. Nonlinear systems of discrete equations were solved with the use of SIMPLER procedures. 3D velocity fields and gas concentrations calculated for galleries are provided. The chief objective is to eliminate the hazardous conditions caused by the presence of gas pollutants emitted by diesel-powered engines in machines and produced in the course of blasting operations. The results of numerical solutions of steady-state velocity field and the time-space field of concentration of gaseous pollutant emitted by lumped or distributed gas sources are presented. The accuracy of numerical representation is evaluated by comparing the prognosticated values with measurements. The obtained physical fields by way of numerical procedures portray the real fields sufficiently well for practical purposes
  • Item type:Article, Access status: Open Access ,
    Próba opisu zjawiska prądów wstecznych metodami CFD
    (2006) Branny, Marian; Broda, Krzysztof; Filek, Krzysztof; Mikołajczyk, Władysław
    An attempt to describe the reverse flow phenomena through numerical simulation was undertaken in this paper. The flow domain creates a 150 m long declined gallery with 15 degrees angle of inclination. The airflow is descending in isotropic conditions. In 10 m long gallery's section a hihger temperature of foor and roof than on remining rock surfaces was assumed. The cosidered problem is described by a system of equations of continuity, Navier-Stokes and energy together with k-epsylon turbulence model. The calculations were performed for different wall temperatures of heated gallery's section. The flow field patterns, characterizing the respective stages of reverse flow expasion are analyzed. CFD code validation based on the experimental data were performed. The numerical calculations by the programme FLUENT 6.1 have been supported.
  • Item type:Article, Access status: Open Access ,
    Wpływ profilu prędkości powietrza na parametry przepływu dwufazowego w szybie wentylacyjnym
    (Wydawnictwa AGH, 2010) Branny, Marian; Nowak, Bernard; Ptaszyński, Bogusław; Kuczera, Zbigniew; Łuczak, Rafał; Życzkowski, Piotr
    Several inflows of water beyond shaft brickwork occur frequently on the length of the upcast shaft. The article describes the results of influence of air velocity profile on the parameters of two-phase flow in the upcast shaft for accepting constant discharge of water flows to the cross-section of shaft with water drops diameter: 0,5 mm, 1 mm, 2 mm, 3 mm.
  • Item type:Article, Access status: Open Access ,
    Wartości współczynników wymiany ciepła i masy w wentylatorowej wyparnej chłodnicy wody
    (Wydawnictwa AGH, 2010) Nowak, Bernard; Filek, Krzysztof; Branny, Marian
    Results of experimental studies of the performance of fan evaporative type of water coolers are presented in this paper. Tests were conducted with two types of coolers - RK-450 and CWW-420. Parameters of cooled and spray water and of the air were measured. On the base of data collected during laboratory experiments, coefficients of heat and mass exchange were calculated for both tested coolers. Among this coefficient are: overall heat-transfer coefficient through membrane (k), convective heat-transfer coefficient (alpha) and coefficient of mass exchange (P) between spray water and the air. There were determined regression lines and coefficients of linear correlation for k and a in dependence of inlet water temperature. The results of experiments and calculations are presented in the form of plots and tables.
  • Item type:Article, Access status: Open Access ,
    Kształt pola prędkości w wyrobiskach przewietrzanych wentylatorami wolnostrumieniowymi - symulacja numeryczna przy użyciu lepkościowych modeli turbulencji
    (Wydawnictwa AGH, 2010) Branny, Marian; Filek, Krzysztof; Nowak, Bernard
    Room and pillar headings are frequently ventilated with the use of jet fans. The range of penetration of an air stream generated by the jet fan is determined by several parameters; the major determinants being the initial stream parameters and the place of fan's installation. The paper presents a method of calculation 3D velocity fields in room and pillar headings. Results obtained with the use of three turbulence models, it is two equations model k-l i k-u SST and one equation of Spalart-Allmaras. Calculation were compared with measurements [Meyer 1993].
  • Item type:Article, Access status: Open Access ,
    Model fazy dyskretnej przepływu powietrza z wykropleniem pary wodnej
    (Wydawnictwa AGH, 2010) Branny, Marian; Nowak, Bernard; Ptaszyński, Bogusław; Kuczera, Zbigniew; Łuczak, Rafał; Życzkowski, Piotr
    The paper describes the use of the discrete phase model to describe the movement of air in the vertical ventilation shafts with condensation of water vapor. Conditions under which discrete phase model can be used were verified and the results of performed calculations were presented. The results were obtained fo vertical movement up to the drops of water in the shaft.
  • Item type:Article, Access status: Open Access ,
    Wpływ parametrów ustalonego przepływu dwufazowego w szybie wentylacyjnym na parametry pracy wentylatora głównego
    (Wydawnictwa AGH, 2009) Branny, Marian; Nowak, Bernard; Ptaszyński, Bogusław; Kuczera, Zbigniew; Łuczak, Rafał; Życzkowski, Piotr
    The two-phase flow, in which a continuous phase is moist air and a discrete phase is water, occurs frequently in the ventilating shafts. Flow of discrete phase, often bidirectional, can cause a change of direction of air flow in the shaft, in spite of function a main fan. In the article, the results of numerical research of influence of the two-phase steady flow in the upcast shaft on the parameters of main fan are described.
  • Item type:Article, Access status: Open Access ,
    Air flow measurements through the laboratory stand of the crossing of the long wall and ventilation gallery for CFD code validation
    (2012) Branny, Marian; Karch, Michał; Wodziak, Waldemar; Szmyd, Janusz; Jaszczur, Marek; Nowak, Remigiusz
    W pracy prezentowane są wyniki badań eksperymentalnych i numerycznych przepływu powietrza przez układ przewodów wentylacyjnych (wyrobisk) w kształcie litery T. Model laboratoryjny jest pewnym uproszczeniem układu wyrobisk skrzyżowania ściany z chodnikiem wentylacyjnym. Uproszczenia dotyczą zarówno geometrii obiektu jak i warunków przepływu. Stanowisko laboratoryjne składa się z kanału dolotowego (końcowy fragment ściany), wnęki i kanału wylotowego (chodnik wentylacyjny) na którego końcu zainstalowano wentylator pracujący w trybie ssącym. Celem przeprowadzonych badań jest próba oszacowania dokładności z jaką symulacje numeryczne odwzorowują przepływ fizyczny. Pomiary prędkości wykonywano metodą PIV (Particle Image Velocimetry). Istota pomiaru polega na statystycznym oszacowaniu ruchu cząstek wskaźnikowych wymieszanych z powietrzem, których ruch rejestrowany jest przez kamerę cyfrową. Cyfrowa rejestracja i korelacja obrazów cząstek umożliwia określenie składowych wektora prędkości w całym obszarze przepływu. Symulację numeryczną przepływu powietrza, dla warunków identycznych jak w badaniach eksperymentalnych wykonano metodą CFD (Computational Fluid Dynamics) przy użyciu programu FLUENT. W pracy testowano dwa modele turbulencji: standardowy k-epsilon i jego modyfikację model RNG k-epsilon. Pomiary wykonano dla średniej prędkości przepływu równej 9,85 m/s czyli przy liczbie Reynoldsa wynoszącej 148 600. Wyniki eksperymentalne porównano z wynikami symulacji numerycznych. Wykonane badania pozwalają na ocenę dokładności z jaką symulacje numeryczne odwzorowują przepływ rzeczywisty. Największe różnice między zmierzonym i obliczonym polem prędkości występują w strefie wnęki. W tej części obszaru przepływu model k-epsilon lepiej niż RNG k-epsilon przybliża warunki rzeczywistego przepływu. Pole prędkości w kanale dolotowym jak i na początku kanału wylotowego obliczane jest z zadawalającą dokładnością jakkolwiek w strefie przepływu wtórnego różnice pomiędzy pomiarami i obliczeniami są znaczące. Dobrą zgodność pomiarów z obliczeniami w tym fragmencie obszaru przepływu uzyskuje się przy użyciu modelu RNG k-epsilon.
  • Item type:Article, Access status: Open Access ,
    Dwufazowy przepływ powietrza i wody w pionowych wyrobiskach górniczych
    (2008) Branny, Marian; Filek, Krzysztof; Nowak, Bernard; Ptaszyński, Bogusław
    The article describes examples of two-phase flows in mining excavations and its impact on ventilation systems. Author discusses some of flows features, parameters and its theoretical models. The article presents computational model of two-phase flows in vertical expiratory shaft, using Euler-Lagrange's method. Numerical simulations were performed with the discrete phase model implemented using computational fluid dynamics (CFD) software- Fluent. Calculations results presented in the form of graphs are enclosed.
  • Item type:Article, Access status: Open Access ,
    Chłodzenie powietrza w wyrobiskach chłodziarką sprężarkową o działaniu bezpośrednim
    (Wydawnictwa AGH, 2011) Branny, Marian; Filek, Krzysztof; Swolkień, Justyna
    Problem of air-cooling in blind headings with duct, exhausting systems of ventilation is considered. Performance of two types of compression refrigerators were tested. Calculations were made for different volume flows of air through evaporator and for different air temperatures in heading. Parameters of cooled air and cooling power of evaporators were calculated using mathematical model of compression refrigerator developed in [1]. The results of calculations are presented in the form of plots and tables. Cooling power of evaporators and its division on sensible and latent part was shown on diagrams.