Repository logo
Article

Automatyczna detekcja elementów asymetrii w dynamicznych mapach CBF perfuzji mózgowej

creativeworkseries.issn1640-7202
dc.contributor.authorHachaj, Roman
dc.date.available2024-11-06T11:36:50Z
dc.date.issued2008
dc.description.abstractThis paper presents a new algorithm that enables detection of asymmetry in dynamic CBF perfusion maps. In the first stage of the algorithm detection of symmetry axis of image (between left and right hemisphere) is performed. In the second stage the level of asymmetry in cerebral blood flow is measured by detection of regions with different perfusion in both brain hemispheres. The algorithm was tested on a set of 28 different images showing or not cerebral blood flow anomalies. The paper also describes the method for estimating cerebral blood flow with a non diffusing contrast agent based on the Meier-Zierler convolution model as well as CBF, CBV, MTT and TTP perfusion maps.en
dc.description.abstractW artykule zaprezentowano nowy algorytm pozwalający na detekcję asymetrii na dynamicznych mapach perfuzji mózgowej CBF. W pierwszym etapie algorytm dokonuje detekcji osi symetrii zobrazowania przechodzącej pomiędzy półkulami mózgowymi. W drugim etapie algorytm ocenia stopień asymetrii przepływu krwi w zobrazowaniu poprzez detekcję regionów o różnym przepływie w obu półkulach mózgowych. Algorytm został przetestowany na 28 zobrazowaniach perfuzyjnych, wśród których znajdowały się zarówno przypadki z nieprawidłowości w przepływie krwi mózgowej, jak i przypadki bez anomalii przepływu. Omówiony został również sposób pomiaru ilości krwi przepływającej przez mózg przy użyciu niedyfundującego wskaźnika w oparciu o konwolucyjny model Meiera-Zierlera oraz sposób konstrukcji map CBF, CBV, MTT i TTP.pl
dc.description.placeOfPublicationKraków
dc.description.versionwersja wydawnicza
dc.identifier.issn1640-7202
dc.identifier.urihttps://repo.agh.edu.pl/handle/AGH/109812
dc.language.isopol
dc.publisherWydawnictwa AGH
dc.relation.ispartofElektrotechnika i Elektronika
dc.rightsAttribution 4.0 International
dc.rights.accessotwarty dostęp
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/legalcode
dc.subjectdynamic CT perfusionen
dc.subjectasymmetry detectionen
dc.subjectMeier-Zierler convolution modelen
dc.subjectdynamic perfusionen
dc.subjectperfusion mapsen
dc.subjectCBFen
dc.subjectdynamiczna perfuzja CTpl
dc.subjectdetekcja asymetriipl
dc.subjectkonwolucyjny model Meiera-Zierlerapl
dc.subjectdynamiczna perfuzjapl
dc.subjectmapy perfuzjipl
dc.subjectCBFpl
dc.titleAutomatyczna detekcja elementów asymetrii w dynamicznych mapach CBF perfuzji mózgowejpl
dc.title.alternativeAutomatic detection of asymmetry elements in dynamic CBF brain perfusion mapsen
dc.title.relatedElektrotechnika i Elektronika
dc.typeartykuł
dspace.entity.typePublication
publicationissue.issueNumberNr 2
publicationissue.paginations. 76-83
publicationvolume.volumeNumberT. 27
relation.isJournalIssueOfPublication1b34e2f5-d27c-47af-bd8f-aa9e168f0a0d
relation.isJournalIssueOfPublication.latestForDiscovery1b34e2f5-d27c-47af-bd8f-aa9e168f0a0d
relation.isJournalOfPublicatione27f22c5-930b-4cca-a825-b1a7f347dbfa

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
elektro.2008.27.2.76.pdf
Size:
583.46 KB
Format:
Adobe Portable Document Format