dc.description.abstractIn this study a formuła was derived to calculate optimum volume of cupola blast air [m /(m -s). standard operating conditions], cold or hot, for single-row coke cupolas, assuming that the lower boun-dary of the melting zone is adhacent to the upper boundary of the combustion zone (the condition of optimum cupola running formulated by A. Achenbach in 1931). Relevant eąuations and tables have also been developed to make the calculations easier. From computations madę in this study it follows that the optimum blast air volume is increasing with an increase of the blast air temperaturę, assuming for cold blast a value close to 100 m /(m -min) (Buzek postulate), with modulus of the metallic charge lumps changing in a rangę of 15 to 20 mm.en
dc.description.abstractW pracy wyprowadzono wzór do obliczania optymalnej ilości powietrza dmuchu [m /(m -s). warunki normalne], zimnego lub podgrzanego, dla żeliwiaków koksowych jednorzędowych, przy założeniu, że dolna granica strefy topienia przylega do górnej granicy strefy spalania (warunek optymalne¬go biegu żeliwiaków, sformułowany przez A. Achenbacha w 1931 roku). Opracowano również wzory i tablice ułatwiające obliczenia. Z przeprowadzonych obliczeń wynika, że ze wzrostem temperatury powietrza dmuchu rośnie optymalna ilość powietrza dmuchu, przy czym dla zimnego dmuchu oscyluje ona około wartości 100m3/(m2mi: 15 do 20 mm.pl
dc.description.versionwersja wydawnicza
dc.identifier.eissn2300-8377
dc.identifier.issn1230-2325
dc.identifier.nukatdd2006318014
dc.identifier.urihttps://repo.agh.edu.pl/handle/AGH/53071
dc.language.isoeng
dc.relation.ispartofMetallurgy and Foundry Engineering
dc.rightsAGH Licence - Fair Use
dc.rights.accessotwarty dostęp
dc.rights.urihttps://repo.uci.agh.edu.pl/info/licence-agh
dc.subjectcupolaen
dc.subjectcokeen
dc.subjectżeliwiakpl
dc.subjectblasten
dc.subjectkokspl
dc.subjectdmuchpl
dc.subjectoptimumen
dc.subjectoptimumpl
dc.titleDetermining optimum volume of cold and hot blast air in single-row coke cupolasen
dc.title.relatedMetallurgy and Foundry Engineering
dc.typeartykuł
dspace.entity.typePublication
publicationissue.issueNumberNo. 1
publicationissue.paginationpp. 53-65
publicationvolume.volumeNumberVol. 31
relation.isJournalIssueOfPublicationc50420d1-430d-4c71-b541-0e76f2e22d93
relation.isJournalIssueOfPublication.latestForDiscoveryc50420d1-430d-4c71-b541-0e76f2e22d93
relation.isJournalOfPublication49768fd2-8e55-4178-b37a-317bbf39ab7c

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
metalur03.pdf
Size:
156.26 KB
Format:
Adobe Portable Document Format