Repository logo
Book Chapter

Assessment of expected tightness of Uhřice-jih underground gas storage

dc.contributor.authorHoráková, Markéta
dc.contributor.authorRado, Robert
dc.contributor.authorBujok, Petr
dc.contributor.authorKlempa, Martin
dc.contributor.authorKunz, Antonín
dc.contributor.authorKřístek, Matěj
dc.date.available2023-07-31T13:23:47Z
dc.date.issued2023
dc.description.abstractUnderground gas storages (UGS) are an essential part of gas transmission systems in almost all countries that consume significant amounts of gas. This is because maximum capacity of transportation system cannot cover increased seasonal or any peak demand. The UGS’s systems are used as buffers to guarantee security and reliability of gas supply. The safety of UGS operation is ensured by the tightness of the storage geological structures, technical and technological equipment, which are known as primary and secondary tightness. This article evaluates the primary tightness conditions of selected Uhřice-jih UGS in the Czech Republic owned by MND Gas Storage a.s. Monitoring and control of the gas quantity balance in the reservoir was carried out using p/z curves method and based on mathematical modelling. In the article some of the aspects of secondary tightness UGS monitoring are also illustrated.en
dc.description.abstractPodziemne magazyny gazu (PMG) są istotną częścią systemów przesyłu gazu w prawie wszystkich krajach, które zużywają znaczne ilości gazu. Wynika to z faktu, że maksymalna przepustowość systemu transportowego nie jest w stanie pokryć zwiększonego sezonowego lub szczytowego zapotrzebowania. Systemy PMG są wykorzystywane jako bufory gwarantujące bezpieczeństwo i niezawodność dostaw gazu. Bezpieczeństwo działania PMG powinno być zapewnione przez szczelność struktur geologicznych magazynu (szczelność pierwotna) oraz wyposażenia technicznego i technologicznego (szczelność wtórna). W artykule dokonano oceny warunków szczelności pierwotnej wybranego PMG Uhřice-jih w Republice Czeskiej należącego do MND Gas Storage a.s. Monitorowanie i kontrolę bilansu ilości gazu w złożu przeprowadzono przy użyciu metody krzywych p/z i z wykorzystaniem modelowania matematycznego. W artykule zilustrowano również niektóre aspekty wtórnego monitorowania szczelności PMG.pl
dc.description.placeOfPublicationKraków]
dc.description.typerozdział
dc.description.versionwersja wydawnicza
dc.identifier.doihttps://doi.org/10.7494/978-83-67427-37-1_5
dc.identifier.isbn978-83-67427-37-1
dc.identifier.urihttps://repo.agh.edu.pl/handle/AGH/105838
dc.language.isoeng
dc.publisherWydawnictwa AGH
dc.relation.ispartofNauka – Technika – Technologia : seria wydawnicza AGH. Tom 7
dc.relation.ispartofseriesNauka – Technika – Technologia : seria wydawnicza AGH, 7
dc.rightsAGH Licence (University Press) - Fair Use
dc.rights.accessotwarty dostęp
dc.rights.urihttps://repo.agh.edu.pl/info/licence-agh-university-press
dc.subjectunderground gas storageen
dc.subjectUGSen
dc.subjectunderground gas storage tightnessen
dc.subjectUGS integrity limitation factors for UGSen
dc.subjectUGS safetyen
dc.subjectgeological structures for UGSen
dc.subjectpodziemne magazyny gazupl
dc.subjectPMGpl
dc.subjectszczelność podziemnych magazynów gazupl
dc.subjectczynniki ograniczające integralność podziemnych magazynów gazupl
dc.subjectbezpieczeństwo PMGpl
dc.subjectstruktury geologiczne dla PMGpl
dc.titleAssessment of expected tightness of Uhřice-jih underground gas storageen
dc.title.alternativeOcena prognozowanej szczelności podziemnego magazynu gazu Uhřice-jihpl
dc.title.relatedNauka – Technika – Technologia : seria wydawnicza AGH. Tom 7
dc.typefragment książki
dspace.entity.typePublication
publicationissue.paginations. 65-78
relation.isAuthorOfPublication1fe9bad7-84d6-4349-b4ed-c90c6a263a7b
relation.isAuthorOfPublication.latestForDiscovery1fe9bad7-84d6-4349-b4ed-c90c6a263a7b
relation.isCompositeOfPartd305d063-32f6-48f8-9925-98d80f6a3df3
relation.isCompositeOfPart.latestForDiscoveryd305d063-32f6-48f8-9925-98d80f6a3df3

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
NTT_7_065.pdf
Size:
2.23 MB
Format:
Adobe Portable Document Format