Browsing by Subject "pore space"
Now showing 1 - 5 of 5
- Results Per Page
- Sort Options
Item type:Article, Access status: Open Access , Fractal analysis of sandstone pore space geometry(Wydawnictwa AGH, 2018) Figiel, Michał; Lewandowska-Śmierzchalska, JoannaFractal analysis is currently one of the fastest evolving branches of science. Numerous objects in nature exhibit a fractal structure. Additionally, the vast majority of rocks - especially reservoir rocks - take the form of a fractal. Computer image analysis based on thin-section images has been used for examining the fractal structure of pore spaces, directly applying the definition of the fractal box-counting dimension. For the examined sandstone sample, thin sections were made and photographed, and the corresponding values of the fractal dimension and lacunarity were calculated. Each of the photos was encompassed by porosity that was calculated based on the number of pixels. Furthermore, the volatility of the fractal dimension and lacunarity were studied as well as their relationships with the porosity. A correlation analysis between the fractal parameters and the porosity was carried out. The results were compared with the data obtained from a mercury porosimetry of the same sample of sandstone.Item type:Thesis, Access status: Restricted , Interpretacja jakościowa i ilościowa przestrzeni porowej piaskowca na podstawie wyników rentgenowskiej tomografii komputerowej(Data obrony: 2018-01-24) Gołda, Piotr
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaPraca polegała na analizie przestrzeni porowej dwóch próbek piaskowców z wykorzystaniem metody rentgenowskiej mikrotomografii komputerowej i podzielona została na części dotyczące przetwarzania obrazów tomograficznych, interpretacji jakościowej oraz ilościowej przestrzeni porowej. Na podstawie przekrojów 2d i obrazu 3d obliczono następujące parametry przestrzeni porowej: porowatość całkowita (wynosząca dla obu próbek: 13.7%), porowatość efektywna (wynosząca dla obu próbek: 13.1%), charakterystyka Eulera (próbka nr 1: -44853, próbka nr 2: -7625). Analizę poprzedzono dyskusją na temat metody badawczej, a zakończono zwięzłymi wnioskami. Uzyskane wyniki zostały zobrazowane w formie tabel, wykresów, zdjęć oraz filmów video, które zostały zamieszczone jako dodatek na płycie cd. Przetwarzanie obrazu wykonano w programie Adobe Photoshop, natomiast interpretacje jakościową i ilościową w programie ImageJ.Item type:Article, Access status: Open Access , New filtration parameters from X-ray computed tomography for tight rock images(Wydawnictwa AGH, 2022) Krakowska-Madejska, Paulina I.New parameters are proposed to evaluate the filtration properties of rocks obtained on the basis of 3D interpretation of images from X-ray computed tomography. The analyzed parameters are: global average pore connectivity, average blind pore connectivity, blind pore coefficient per object and blind pore coefficient per branch. The 3D pore space from computed X-ray tomography must be subjected to a process of pore space transformation into a skeleton. Then, the presented parameters can be evaluated, taking into consideration the pore channels (branches), pore channel connection points (junctions) and blind pores (pore without connection to the other pore). The calculations were made for low porosity sandstones, mudstones, limestones, and dolomites which differ in terms of age and depth of present deposition. The global average pore connectivity reflects the degree of development of the pore space in which the formation fluid can flow. The higher the global average pore connectivity, the most complex the pore structure can be expected. The higher the parameter of the average blind pore connectivity, the worse are the filtration properties of the rock. The higher the concentration of blind pore coefficient per object or branch, the worse the filtration properties of the rock. Moreover, new parameters were compared with the Euler characteristic and coordination number, revealing a high consistency.Item type:Thesis, Access status: Restricted , Opis przestrzeni porowej skał w przestrzeni 3D(Data obrony: 2019-01-24) Lango, Agata
Wydział Geologii, Geofizyki i Ochrony ŚrodowiskaCelem projektu była analiza przestrzeni porowej próbki oraz zbadanie zmienności wartości porowatości mierzonej dla obrazów 2D i 3D. W projekcie obiektem badań były wyniki rentgenowskiej tomografii komputerowej (micro-CT) wykonanej na próbce piaskowca. Za pomocą skryptów pisanych w programie Matlab przeanalizowano przestrzeń porową pod kątem objętości porów do objętości skały, wielkości porów oraz stopnia ich połączenia. Największy udział w przestrzeni porowej próbki przypadł na pory połączone o wielkości od 105 μm3 do 106 μm3. Przeprowadzono także symulację jak zmienia się obliczona wartość porowatości przy użyciu zwiększającej się liczby obrazów 2D. Analiza wyników wykazała, że wiarygodny wynik można uzyskać przy zbadaniu porowatości z równo oddalonych przekrojów stanowiących przynajmniej 5 % obrazu 3D. Dodatkowo zaobserwowano anizotropię porowatości w próbce oraz znaczne różnice w mierzonej porowatości w różnych jej fragmentach.Item type:Article, Access status: Open Access , Wizualizacja przestrzeni porowej skał z wykorzystaniem mikrotomografii rentgenowskiej(Wydawnictwa AGH, 2009) Zalewska, Jadwiga; Dohnalik, MarekRoentgen computed microtomography (micro-CT) allows visualizing internal structure of measured objects determined by density differences. Micro-CT measurements enable obtaining of many parallel 2D cross sections, which allows to project in 3D particular properties. Main micro-CT applications are porosity measurements and visualizations. The paper shows first results of measurements and imaging of rock porous space, using micro-CT method.
