Abstract

This work is a development for T. Ozog's theory by introducing two-parameter Wieghardt's contact. The formulas for beam deflection, reaction of foundation, bending moments, shear forces and the elastic energy of the cantilever beam are derived and discussed. The failure limit of the cantilever span is also calculated.


Praca stanowi rozwinięcie pracy T. Ozoga poprzez wprowadzenie kontaktu dwuparametrowego typu Wieghardta. Wyprowadzono dla stropu wzory na obliczenie ugięć, kąta obrotu, naprężeń, sił przekrojowych: M(x) - momentu zginającego, Q(x) - siły tnącej. Ponadto wyznaczono dla wspornika energię sprężystą i jej rozkład na część odpowiadającą za zmianę objętości i część dotyczącą zmiany postaci. Wyznaczono również graniczną długość wspornika, przy której następuje jego zniszczenie.