An investigation into the influence of a temperature load of a suspended roof in measurements for diagnostic purposes
| creativeworkseries.issn | 1898-1135 | |
| dc.contributor.author | Deska, Krzysztof | |
| dc.date.available | 2017-08-31T07:30:08Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | This paper presents issues concerning the necessity and possibility of including a temperature load of a suspended, open structure, especially in terms of correct identifying a displacement caused by snow and ice loads. Using statistical analysis tools, based on the results of periodic measurements, appropriate calculations were carried out. Both possibilities and limitations of this approach and the use of outcomes were indicated and the need for and directions of a continued research in this area were demonstrated. | en |
| dc.description.abstract | W pracy przedstawiono problematykę dotyczącą konieczności i możliwości uwzględnienia obciążenia temperaturą konstrukcji otwartego przekrycia wiszącego, przede wszystkim w aspekcie prawidłowego określenia przemieszczeń wywołanych obciążeniem śniegiem i lodem. Wykorzystując narzędzia analizy statystycznej oraz opierając się na wynikach pomiarów okresowych, przeprowadzono stosowne obliczenia. Omówiono zarówno możliwości, jak i ograniczenia zastosowanego podejścia i wykorzystania wyników prac oraz wykazano konieczność i kierunki kontynuacji badań w tym zakresie. | pl |
| dc.description.placeOfPublication | Kraków | |
| dc.description.version | wersja wydawnicza | |
| dc.identifier.doi | https://doi.org/10.7494/geom.2013.7.1.47 | |
| dc.identifier.eissn | 2300-7095 | |
| dc.identifier.issn | 1898-1135 | |
| dc.identifier.nukat | dd2014318091 | |
| dc.identifier.uri | https://repo.agh.edu.pl/handle/AGH/47056 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Geomatics and Environmental Engineering | |
| dc.rights | Attribution 4.0 International | |
| dc.rights.access | otwarty dostęp | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/legalcode | |
| dc.subject | suspended roof | en |
| dc.subject | measurements | en |
| dc.subject | przekrycie wiszące | pl |
| dc.subject | temperature load | en |
| dc.subject | pomiary | pl |
| dc.subject | obciążenie temperaturą | pl |
| dc.subject | snow load | en |
| dc.subject | obciążenie śniegiem | pl |
| dc.title | An investigation into the influence of a temperature load of a suspended roof in measurements for diagnostic purposes | en |
| dc.title.alternative | Badanie wpływu obciążenia temperaturą konstrukcji przekrycia wiszącego w pomiarach na potrzeby diagnostyczne | pl |
| dc.title.related | Geomatics and Environmental Engineering | en |
| dc.type | artykuł | |
| dspace.entity.type | Publication | |
| publicationissue.issueNumber | No. 1 | |
| publicationissue.pagination | pp. 47-56 | |
| publicationvolume.volumeNumber | Vol. 7 | |
| relation.isJournalIssueOfPublication | d5eafd6c-f717-4e6d-9452-b8ad5891d4a4 | |
| relation.isJournalIssueOfPublication.latestForDiscovery | d5eafd6c-f717-4e6d-9452-b8ad5891d4a4 | |
| relation.isJournalOfPublication | 102998b2-3fd0-4247-98bf-973d6a9ba2d9 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- geom.2013.7.1.47.pdf
- Size:
- 683.9 KB
- Format:
- Adobe Portable Document Format