An investigation into the influence of a temperature load of a suspended roof in measurements for diagnostic purposes

creativeworkseries.issn1898-1135
dc.contributor.authorDeska, Krzysztof
dc.date.available2017-08-31T07:30:08Z
dc.date.issued2013
dc.description.abstractThis paper presents issues concerning the necessity and possibility of including a temperature load of a suspended, open structure, especially in terms of correct identifying a displacement caused by snow and ice loads. Using statistical analysis tools, based on the results of periodic measurements, appropriate calculations were carried out. Both possibilities and limitations of this approach and the use of outcomes were indicated and the need for and directions of a continued research in this area were demonstrated.en
dc.description.abstractW pracy przedstawiono problematykę dotyczącą konieczności i możliwości uwzględnienia obciążenia temperaturą konstrukcji otwartego przekrycia wiszącego, przede wszystkim w aspekcie prawidłowego określenia przemieszczeń wywołanych obciążeniem śniegiem i lodem. Wykorzystując narzędzia analizy statystycznej oraz opierając się na wynikach pomiarów okresowych, przeprowadzono stosowne obliczenia. Omówiono zarówno możliwości, jak i ograniczenia zastosowanego podejścia i wykorzystania wyników prac oraz wykazano konieczność i kierunki kontynuacji badań w tym zakresie.pl
dc.description.placeOfPublicationKraków
dc.description.versionwersja wydawnicza
dc.identifier.doihttps://doi.org/10.7494/geom.2013.7.1.47
dc.identifier.eissn2300-7095
dc.identifier.issn1898-1135
dc.identifier.nukatdd2014318091
dc.identifier.urihttps://repo.agh.edu.pl/handle/AGH/47056
dc.language.isoeng
dc.relation.ispartofGeomatics and Environmental Engineering
dc.rightsAttribution 4.0 International
dc.rights.accessotwarty dostęp
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/legalcode
dc.subjectsuspended roofen
dc.subjectmeasurementsen
dc.subjectprzekrycie wiszącepl
dc.subjecttemperature loaden
dc.subjectpomiarypl
dc.subjectobciążenie temperaturąpl
dc.subjectsnow loaden
dc.subjectobciążenie śniegiempl
dc.titleAn investigation into the influence of a temperature load of a suspended roof in measurements for diagnostic purposesen
dc.title.alternativeBadanie wpływu obciążenia temperaturą konstrukcji przekrycia wiszącego w pomiarach na potrzeby diagnostycznepl
dc.title.relatedGeomatics and Environmental Engineeringen
dc.typeartykuł
dspace.entity.typePublication
publicationissue.issueNumberNo. 1
publicationissue.paginationpp. 47-56
publicationvolume.volumeNumberVol. 7
relation.isJournalIssueOfPublicationd5eafd6c-f717-4e6d-9452-b8ad5891d4a4
relation.isJournalIssueOfPublication.latestForDiscoveryd5eafd6c-f717-4e6d-9452-b8ad5891d4a4
relation.isJournalOfPublication102998b2-3fd0-4247-98bf-973d6a9ba2d9

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
geom.2013.7.1.47.pdf
Size:
683.9 KB
Format:
Adobe Portable Document Format