Repository logo
Article

Application of selected balance methods to the evaluation of performance parameters of the extraction back-pressure power unit in a combined heat and power plant

Loading...
Thumbnail Image

Date

Presentation Date

Editor

Other contributors

Access rights

Access: otwarty dostęp
Rights: AGH Licence
AGH Licence - Fair Use

Licencja AGH - Fair use of copyrighted works

Other title

Zastosowanie wybranych metod bilansowych do oceny efektywności pracy bloku upustowo-przeciwprężnego elektrociepłowni

Resource type

Version

wersja wydawnicza
Item type:Journal Issue,
Mechanics
2008 - Vol. 27 - No. 1

Pagination/Pages:

s. 43-53

Research Project

Event

Description

Bibliografia s. 52.

Abstract

Thermal measurements of the extraction back-pressure power unit in the combined heat and power plant for a wide range of working loads were utilised to develop an algorithm for computing performance parameters of the power unit. The calculation procedures use the enthalpy balance method and the entropy balance method. Adequacy of the two methods was compared on the basis of performance characteristics of the investigated power unit.


Na podstawie pomiarów cieplnych bloku upustowo-przeciwprężnego elektrociepłowni, przeprowadzonych w szerokim zakresie obciążeń eksploatacyjnych, opracowano algorytm obliczeń podstawowych parametrów charakteryzujących pracę bloku. W tym celu przeprowadzono wymagane obliczenia, wykorzystując zasady entalpowej i entropowej metody bilansowej. Następnie dokonano analizy porównawczej przydatności obu metod do sformułowania poprawności oceny efektywności pracy badanego bloku.