In the present paper several calibration methods for eye movement acquisition devices: simple linear, linear with two calibration points, second order polynomial, linear neural network and radial based functions neural networks were described and tested. The methods were tested in two experiments: following eye movements on an elliptical trajectory and gaze fixations in randomly placed points on the screen on six subjects. Results of the experiments were described and discussed.
W artykule opisano i przetestowano szereg metod kalibracji urządzeń do akwizycji ruchu gałki ocznej: prostej metody liniowej, metody liniowej wykorzystującej dwa punkty kalibracyjne, metody nieliniowej z wielomianem drugiego stopnia, liniowych sieci neuronowych i sieci neuronowych z radialnymi funkcjami bazowymi (RBF). Metody kalibracji przetestowano na sześciu osobach w dwóch eksperymentach: wodzeniu po trajektorii eliptycznej i skupianiu wzroku w punktach losowo rozmieszczonych na ekranie. Wyniki przeprowadzonych eksperymentów zostały opisane i omówione.